Trelawny Dust Collectors A22, A45 & ATEX KAV30
A45 - three motors, detachable bin
Capture dust at source and keep operators and the environment protected. The single-phase A22 and A45 are Class M collectors for scarifiers and grinders, with an optional H14 HEPA filter; the KAV30 is ATEX-approved for Gas Zone 1 / Dust Zone 21 and forms the heart of Trelawny's TVS® tool-and-vacuum system.
Three motors, one Class M filter
The A45 figures on this page, pinned to the machine. Hover or tap a number to trace it to the hardware.
- 01Motor head3.0-3.5 kWThree single-phase motors. 76 dB(A).
- 02Inlet540 m³/hAir flow 150 l/s, vacuum 2,500 mm H₂O. Complete with a 50 mm tool kit.
- 03FilterClass MOptional H14 HEPA filter. A better filter does not make it an H-class machine.
- 04ContainmentBin or ENDLESSBAGDetachable bin, or the ENDLESSBAG safe containment system.
- 05Frame65 kgFull steel construction.
Configure Your Dust Collector
Start with the dust, because the dust class decides the machine. A few more choices give you one exact Trelawny part number, and what it needs to run.
Already know your part number?
Skip the builder and order straight from the full list. Every collector, filter, hose and bag, with its Trelawny part number.
Which collector for which tool
- TFP200, hand and floor grindersSmaller single-phase machinesA22. Trelawny's compact partner for the TFP200 scarifier and smaller construction equipment.
- More dust than the A22 can takeLarger scarifiers, floor grinders, large volumes of fine dustA45. Three single-phase motors, 540 m³/h.
- Handheld TVS® scaling tools, or an ATEX Category 2 areaRuns off the tools' own airKAV30. Pneumatic, certified for Gas Zone 1 and Dust Zone 21. TVS scalers →
- Leaded, silica or any CMR dustWhatever the toolA certified Type H machine, such as the KAV30 Dry Type H. The A22 and A45 are Class M: see dust class.
Which dust class does your material need?
Industrial vacuums are classified under EN 60335-2-69 by the hazard of the dust they are certified for. Since 27 June 2026 the Danish lead limit is 0.03 mg/m³, below the 0.1 threshold, and lead carries a non-threshold reprotoxic notation: leaded coating dust is H class on both grounds, and respirable crystalline silica sits in the same bracket.
| Class | For substances with a limit of | Max. penetration |
|---|---|---|
| L | above 1 mg/m³ | under 5% |
| M | 0.1 mg/m³ or above | under 0.5% |
| H | below 0.1 mg/m³, plus all CMR substances and carcinogens | under 0.005% |
An M-class machine is not adequate for lead paint, and cannot be made adequate. The class applies to the complete machine: filter, seals, housing and disposal system. A better filter does not make an H-class unit.
Trelawny lists the A22 and A45 as Class M with an optional H14 HEPA filter. EN 1822 filter class H14 and EN 60335-2-69 dust class H are different tests, so treat the A22 and A45 as machines for general surface-prep debris, and specify a certified Type H machine, such as the KAV30 Dry Type H (303.10KAV30/DH), for leaded, silica or CMR dust. Unsure which applies? Ask us before ordering.
Trelawny states each K Series machine ships with a filtration test certificate, above 99.995% at 0.6 microns: Trelawny's own filtration test, not the EN 60335-2-69 dust-class test. The full argument: dust control for lead paint.
Capture at the tool, not just in the compartment
Trelawny's Tool & Vacuum System (TVS) clamps a shroud over the needle bundle with a 38 mm take-off straight into the collector, so dust is caught in the same pass as the removal. A US EPA study on bridge steel found a vacuum-shrouded needle gun cut airborne respirable dust and lead particulate by up to 99%, and hazardous waste by up to 97.5%.
- The shrouds retrofit: 418.2003 fits the VL203 and VL223, 418.3003 the VL303, 418.2200 the 2B and 2BPG, 418.3040 the 3BPG. Scalers already aboard need shrouds, cuffs and a collector, not replacing.
- Cuff shape is a real decision. Flat, edge and corner cuffs are separate part numbers; a flat cuff on a curved frame is a leak path.
- Budget the air. KAV30 16 l/s (35 cfm) plus a VL203's 1.89 l/s (4 cfm) is about 39 cfm per station, roughly 90% of it the vacuum.
- Extraction is LEV, and LEV has an owner. Inspect, maintain and test it; filters block and airflow drops without any visible sign.
- Not for light metal. Needle scalers pit thin plate and aluminium, shrouded or not.

Keep planning
Dust control for needle scaling lead paint
The 2026 limits, why H class, and a collector selector.
Read the guide → ProductsTVS shrouds and needle scalers
Shrouds that retrofit to the scalers already in the locker.
View the range → ProductsThe ATEX range
The KAV30 with the VL-Ex scalers and SF-Ex hammers it serves.
View the range →Build Your Quote
Your selected items appear below automatically.
Quote Request Sent!
Thank you. Your enquiry is on its way to the SepcoTech team. We'll respond within one business day.