Portasonic PRO - 7" tablet, sensors clamped on the pipe
Coltraco's clamp-on transit-time flow meters strap onto the outside of a pipe and read the flow inside it ultrasonically, to ±0.5%, on lines from DN15 up to DN2500 (with the large DS10 sensor). Monitor fuel lines, check water and fire-sprinkler lines, or confirm a pump is delivering to spec: nothing is cut, nothing is drained, and the system keeps running while you measure.
Two sensors outside, the flow read inside
Every figure on this page lives somewhere on the kit. Hover or tap a number to trace it to the hardware.
- 01Tablet7" touchscreenA rugged IP67 tablet with a built-in battery for at least 10 hours of continuous use.
- 02Flow reading±0.5%Full transit-time flow metering, read on screen and logged or exported.
- 03Pressure reading±5%Non-invasive internal pressure calculation, alongside the flow.
- 04Sensor pairClamp-onTransit-time sensors on the outside of the pipe, fixed with beaded-chain clamps.
- 05PipeDN15–DN750The standard DM10 sensors; enter pipe size, material and wall thickness so the meter knows the path length.
Portable & Fixed Clamp-On Flow Meters
From a handheld survey meter to a permanently installed flow & heat meter. Add any of them to your quote.
PortablePortasonic® PLUS
A lightweight portable transit-time flow meter that also gauges pipe-wall thickness, letting you measure, record and export flow on almost any pipe material and fluid from a pre-programmed database.
Key specifications
| Type | Portable clamp-on transit-time flow meter |
| Accuracy | ±0.5% |
| Pipe range | DN15–DN700 (DM10); to DN2500 with the optional DS10 sensor |
| Extra | Built-in pipe-wall thickness gauge |
| Weight | 434 g |
| Data | Internal logging & export |
+ Pressure Calc.Portasonic® PRO
The advanced portable system on a 7" tablet: full transit-time flow metering plus a non-invasive internal pressure calculation, with survey data stored in the app and exported by USB or email.
Key specifications
| Type | Portable tablet clamp-on flow meter |
| Flow accuracy | ±0.5% |
| Pressure calc. | Non-invasive, ±5% |
| Pipe range | DN15–DN750 (DM10) |
| Display | 7" touchscreen tablet |
| Data | Stored in the app; USB-C or email export |
Fixed InstallPermaflow®
A permanently installed clamp-on transit-time meter for continuous flow and heat monitoring. It stays non-invasive on the pipe, with optional PT100 heat metering and industrial outputs as plug-in modules.
Key specifications
| Type | Fixed clamp-on transit-time flow & heat meter |
| Accuracy | ±0.5% |
| Velocity | 0.01–25 m/s |
| Pipe range | DN15–DN2500 (standard DM10 sensors DN15–DN700; large DS10 sensors DN25–DN2500) |
| Heat metering | Optional: two PT100 input modules for supply and return (thermometers not included) |
| Outputs | Modbus / 4–20 mA options |
Clamping On a Flow Meter, Step by Step
Measure flow on a live line in minutes, no cutting, no shutdown.
Measure the pipe
Enter pipe size, material and wall thickness so the meter knows the path length.
Apply couplant
Apply ultrasonic couplant to the sensor faces for a clean signal into the pipe.
Clamp the sensors
Mount the transit-time sensors with the beaded-chain clamps, in the V, W or Z arrangement that gives a sound path of 100 mm or more in the fluid.
Read & export
Read the flow rate on the display and log or export the data, or leave Permaflow monitoring 24/7.
Where it's used aboard
Portasonic PLUS vs PRO vs Permaflow
| Portasonic PLUS | Portasonic PRO | Permaflow | |
|---|---|---|---|
| Type | Portable | Portable (tablet) | Fixed install |
| Accuracy | ±0.5% | ±0.5% | ±0.5% |
| Pipe range | DN15–DN700; DN2500 with DS10 | DN15–DN750 | DN15–DN700; DN2500 with DS10 |
| Extra capability | Pipe-wall thickness gauge | Pressure calc (±5%) | 24/7 monitoring · optional PT100 heat · Modbus / 4–20 mA modules |
| Best for | Spot surveys & commissioning | Advanced survey + pressure | Permanent monitoring & heat metering |
Flow Metering, Demonstrated
Footage published by Coltraco Ultrasonics showing the Portasonic® and Permaflow® meters in use.
Transit-time flow, read from outside the pipe
A pair of ultrasonic sensors clamp to the pipe wall. The meter times a pulse sent with the flow against one sent against it, and the tiny difference gives the flow velocity, and from the pipe data, the flow rate. Because the sensors never touch the fluid, there's no pipe-cutting, no leak path and no shutdown, which is suited to fuel, water and process lines aboard ship and ashore. Choose the portable Portasonic® for spot surveys and commissioning, or the permanently installed Permaflow® for continuous monitoring and heat metering. Note: these are flow meters, not leak detectors. For watertight integrity, see the Portascanner range.
What ships, and what to plan around
The three kits as Coltraco lists them, and the conditions that decide which meter fits the pipe.
What ships: Portasonic PLUS
3-year warranty on the unit, 1 year on the sensors.
- Main unit
- One pair of DM10 standard sensors
- One pair of beaded chain clamps
- 10 mm ultrasonic thickness gauge probe
- Ultrasonic couplant, measuring tape
- User and installation manuals
- Calibration certificate, robust carrying case
What ships: Portasonic PRO
3-year warranty on the unit, 1 year on the sensors.
- 7" tablet
- Processing unit with a pair of DM10 sensors (DN15-DN750)
- Pair of beaded chain clamps
- Measuring tape, ultrasonic couplant
- USB-C cable, USB-C to USB-A adaptor, USB stick
- User and installation manuals
- Calibration certificate, robust carrying case
What ships: Permaflow
3-year warranty on the unit, 1 year on the sensors.
- Main unit (RS232 and USB communications included)
- Mains power supply
- Pair of jubilee clips for your pipe size
- USB cable
- Measuring tape, ultrasonic couplant
- User and installation manuals
- Calibration certificate
Plan around these
As stated in Coltraco's own brochures. We confirm anything else on the quote.
- Clean liquids only: most clean liquids with gas or solids under 10% of the volume. The ±0.5% is under ideal conditions.
- The sensor sets the pipe size: the standard DM10 covers DN15-DN700 (the PRO brochure states DN750). The large DS10 (DN25-DN2500) is an option for the PLUS and Permaflow; no large sensor is listed for the PRO.
- Mounting: V (2 passes), W (4) or Z (1). Coltraco recommends the pass count that gives a sound path of 100 mm or more in the fluid.
- One job each: only the PLUS gauges pipe-wall thickness (2-20 mm); only the PRO calculates internal pressure (±5%), and it calculates rather than measures it.
- Permaflow is fixed: mains or DC powered (DC PSU supplied for 100-240 V AC), not battery. Outputs (4-20 mA, Modbus RTU, relay, OPTO, open collector, digital) and PT100 inputs are plug-in modules; heat metering needs two PT100 modules, thermometers not included.
- Permaflow sensors: Coltraco lists the DM10 and DS10 transducers and the carrying case as accessories, so we confirm the sensor set on the quote.
Flow Meters: FAQ
Do I have to cut into the pipe?
Portable or fixed?
What pipe sizes does it cover?
How accurate is it?
Clean or dirty liquids?
What are typical marine uses?
Build Your Quote
Your selected instruments appear below automatically. Send everything in one request.
Quote Request Sent!
Thank you, your selected instruments are on their way to the SepcoTech team. We'll respond within one business day.